Reference | Description | Material | Placement | Max. length (mm) | Width (mm) | Thickness (mm) |
---|---|---|---|---|---|---|
AU 06 D | Absorbent-insulating folded panels | Aluminium | Horizontally inside HEA | 5000 | 600 | 92 |
AU 06 F | Absorbent-insulating folded panels | Galvanized steel + aluminium | Horizontally inside HEA | 5000 | 500 | 85 |
AUP 03 | Absorbent-insulating profiled panels | Aluminium | Horizontally inside and in front of HEA structure | 5000 | 500 | 124 |
DE 25 | Absorbent-insulating folded panels | Aluminium | Vertically in front of HEA structure | 4000 | 500 to 750 | 84 + 84 |
TU 05 | Absorbent folded panels | Aluminium | Vertically in front of wall | 7000 | 500 tot 750 | 72 |
Absorbent-insulating panels
Absorbent and insulating metallic noise barriers consist of a folded or profiled rear box made of aluminum or galvanized steel.
They are filled with a mineral wool of varying thickness and density adapted to each type of use.
The front of the panel is protected by a perforated aluminium sheet.
After manufacture, the product is thermo-painted by polyester coating, completed, as an option, by an anti-graffiti treatment.
AU 06 D
Panels superposed horizontally in HEA profiles.
Maximum length: 5000 mm // Width: 600 mm // Thickness: 92 mm
Composition:
- Absorbent mineral wool protected by a black anti-defibratory veil
- “C” folded aluminium box
- Perforated aluminium grid
- Thermo-painted assembly
Acoustical characteristics:
In situ values
- Acoustical reflection: DLRI = 6 to 8 dB according to EN 1793-5
- Insulation in the middle of the panels: DLSI,E = 29 to 31 dB according to EN 1793-6
- Insulation at the right of the poles: DLSI,P = 29 to 30 dB according to EN 1793-6
Laboratory values
- Sound absorption: DLα,NRD = 11 dB according to EN 1793-1
- Insulation: DLR = 25 dB according to EN 1793-2
AU 06 F
Panels superposed horizontally in HEA profiles.
Maximum length: 5000 mm // Width: 500 mm // Thickness: 85 mm
Composition:
- Absorbent mineral wool protected by a black anti-defibratory veil
- “C” folded box in galvanized steel
- Perforated aluminium grid
- Thermo-painted assembly
Acoustical characteristics:
In situ values
- Acoustical reflection: DLRI = 6 dB according to EN 1793-5
- Insulation in the middle of the panels: DLSI,E = 38 dB according to EN 1793-6
- Insulation at the right of the poles: DLSI,P = 35 dB according to EN 1793-6
Laboratory values
- Sound absorption: DLα,NRD = 14 dB according to EN 1793-1
- Insulation: DLR = 28 dB according to EN 1793-2
AUP 03
Panels superposed horizontally in or in front of HEA profiles.
Maximum length: 5000 mm // Width: 500 mm // Thickness: 124 mm
Composition:
- Absorbent mineral wool protected by a black anti-defibratory veil
- Profiled aluminium box
- Perforated aluminium grid
- Thermo-painted assembly
Acoustical characteristics:
In situ values
- Acoustical reflection: DLRI = 5 dB according to EN 1793-5
- Insulation in the middle of the panels: DLSI,E = 33 dB according to EN 1793-6
- Insulation at the right of the poles: DLSI,P = 33 dB according to EN 1793-6
Laboratory values
- Sound absorption: DLα,NRD = 12 dB according to EN 1793-1
- Insulation: DLR = 25 dB according to EN 1793-2
DE 25
Panels placed vertically between horizontal rails in front of the supporting structure.
Maximum length: 4000 mm // Width: 500 to 750 mm // Thickness: 84+84 mm
Composition:
- Absorbent mineral wool protected by a black anti-defibratory veil
- “C” folded aluminium box
- Perforated aluminium grid
- Upper rail in galvanized steel
- Extruded aluminium bottom rail
- Thermo-painted assembly
Acoustical characteristics:
In situ values
- Acoustical reflection: DLRI = 5 dB according to EN 1793-5
- Insulation in the middle of the panels: DLSI,E = 30 dB according to EN 1793-6
- Insulation at the right of the poles: DLSI,P = 30 dB according to EN 1793-6
Laboratory values
- Sound absorption: DLα,NRD = 10 dB according to EN 1793-1
- Insulation: DLR = 25 dB according to EN 1793-2
Absorbent panels
Our absorbent metallic noise barriers have been specially designed to effectively absorb sound waves in tunnel access and exits.
They are also used as absorbent siding, along traffic lanes, workshops, sports halls, …
They consist of a perforated aluminum sheet, filled with a panel of mineral wool.
After manufacture, the product is thermo-painted by polyester powdering, completed, as an option, by an anti-graffiti treatment.
TU 05
Panels placed vertically along a wall, between horizontal rails.
Maximum length: 7000 mm // Width: 500 to 750 mm // Thickness: 72 mm
Composition:
- Absorbent mineral wool protected by a black anti-defibratory veil
- Perforated aluminium sheet
- Upper rail in aluminium or galvanized steel
- Extruded aluminium bottom rail
- Thermo-painted or anodized assembly
Acoustical characteristics:
In situ values
- Acoustical reflection: DLRI = 6 dB according to EN 1793-5
Laboratory values
- Sound absorption: DLα,NRD = 11 dB according to EN 1793-1